{"product_id":"bskh66198","title":"Human Solute Carrier Family 30, Member 10 (SLC30A10) ELISA Kit","description":"\u003cmeta charset=\"utf-8\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003ePrinciple of the Assay\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe microtiter plate provided in this kit has been pre-coated with an antibody specific to SLC30A10. Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody preparation specific to SLC30A10. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After the TMB substrate solution is added, only those wells that contain SLC30A10, biotin-conjugated antibody, and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution, and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of SLC30A10 in the samples is then determined by comparing the O.D. of the samples to the standard curve.\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003eFor Use with tissue homogenates or other biological fluids. For Research Use Only. Not for use in diagnostic procedures.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\" class=\"image\"\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eTarget Information\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003ePlays a pivotal role in manganese transport. Manganese is an essential cation for the function of several enzymes, including some crucially important for the metabolism of neurotransmitters and other neuronal metabolic pathways. However, elevated levels of manganese are cytotoxic and induce oxidative stress, mitochondrial dysfunction and apoptosis. Acts as manganese efflux transporter and confers protection against manganese-induced cell death (PubMed:22341972, PubMed:22341971, PubMed:25319704, PubMed:27226609, PubMed:27307044). Also acts as zinc transporter involved in zinc homeostasis. Seems to mediate zinc transport into early endosomes and recycling endosomes to prevent zinc toxicity; the function may be regulated by heterodimerization with other zinc transporters of the SLC30A subfamily. The SLC30A3:SLC30A10 heterodimer is involved in zinc transport-dependent regulation of the EGFR\/ERK transduction pathway in endosomes. May be involved in regulation of zinc-dependent senescence of vascular smooth muscle cells (PubMed:22706290, PubMed:22427991, PubMed:26728129).\u003c\/p\u003e\n\u003ctable data-mce-fragment=\"1\" cellpadding=\"0\" cellspacing=\"0\" border=\"0\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eGENE ID\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" class=\"header\"\u003e\u003ca href=\"https:\/\/www.ncbi.nlm.nih.gov\/gene\/55532\" title=\"55532\" target=\"_blank\" rel=\"noopener noreferrer\" data-mce-href=\"https:\/\/www.ncbi.nlm.nih.gov\/gene\/55532\"\u003e55532\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eSWISS PROT\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" class=\"header\"\u003e\u003ca href=\"https:\/\/www.uniprot.org\/uniprot\/Q6XR72\" title=\"Q6XR72\" target=\"_blank\" rel=\"noopener noreferrer\" data-mce-href=\"https:\/\/www.uniprot.org\/uniprot\/Q6XR72\"\u003eQ6XR72\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eSYNONYMS\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" class=\"header\"\u003e\n\u003cmeta charset=\"utf-8\"\u003eZnT-10; ZRC1; ZNT8; Zinc Transporter 8\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\n\u003cbr\u003eMaterials Supplied\u003c\/h3\u003e\n\u003ctable data-mce-fragment=\"1\" cellpadding=\"0\" cellspacing=\"0\" border=\"0\"\u003e\n\u003cthead data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003cth data-mce-fragment=\"1\"\u003eKit Components\u003c\/th\u003e\n\u003cth data-mce-fragment=\"1\" class=\"header\"\u003e96 Wells Quantity\/Size\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003ePre-coated, ready-to-use 96-well strip plate\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" class=\"header\"\u003e1 plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003ePlate sealer for 96 wells\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" class=\"header\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eStandard\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" class=\"header\"\u003e2 tubes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eDiluent buffer\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" class=\"header\"\u003e1 bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eDetection Reagent A\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" class=\"header\"\u003e1 bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eDetection Reagent B\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" class=\"header\"\u003e1 bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eTMB Substrate\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" class=\"header\"\u003e1 tube\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eStop Solution\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" class=\"header\"\u003e1 tube\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eWash Buffer (30 ℅ concentrate)\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" class=\"header\"\u003e1 tube\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eProduct data sheet\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" class=\"header\"\u003e1 copy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eStorage\u003c\/h3\u003e\n\u003ctable data-mce-fragment=\"1\" cellpadding=\"0\" cellspacing=\"0\" border=\"0\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" class=\"header\"\u003eStorage\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eThe TMB Substrate, Wash Buffer (30X concentrate), and the Stop Solution should be stored at 4°C upon receipt, while the other items should be stored at -20°C.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003ePerformance Characteristics\u003c\/h3\u003e\n\u003ctable data-mce-fragment=\"1\" cellpadding=\"0\" cellspacing=\"0\" border=\"0\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" class=\"header\"\u003eREPEATABILITY\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp\u003eIntra-assay Precision (Precision within an assay): 3 samples with low, middle, and high-level SLC30A10 were tested 20 times on one plate, respectively.\u003cbr\u003eInter-assay Precision (Precision between assays): 3 samples with low, middle, and high-level SLC30A10 were tested on 3 different plates, with 8 replicates in each plate.\u003cbr\u003eCV(%) = SD\/meanX100\u003cbr\u003e\u003cbr\u003eIntra-Assay: CV\u0026lt;10%\u003cbr\u003eInter-Assay: CV\u0026lt;12%\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" class=\"header\"\u003eSENSITIVITY\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eThe minimum detectable dose was 0.054ng\/mL.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" class=\"header\"\u003eASSAY RANGE\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e0.156-10ng\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" class=\"header\"\u003eSPECIFICITY\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eThis assay has high sensitivity and excellent specificity for the detection of SLC30A10.\u003cbr\u003eNo significant cross-reactivity or interference between SLC30A10 and analogs was observed.\u003cbr\u003eNote:\u003cbr\u003eLimited by current skills and knowledge, it is impossible to perform all possible cross-reactivity detection tests between SLC30A10 and all analogs, therefore, cross reactivity may still exist.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Bioss","offers":[{"title":"96T","offer_id":41092333764659,"sku":"BSKH66198-96T","price":750.0,"currency_code":"USD","in_stock":true},{"title":"48T","offer_id":41092333797427,"sku":"BSKH66198-48T","price":525.0,"currency_code":"USD","in_stock":true}],"url":"https:\/\/www.biossusa.com\/products\/bskh66198","provider":"Bioss","version":"1.0","type":"link"}