Human Ubiquilin 2 (UBQLN2) ELISA Kit

Due to the possibility of mismatching between antigens from other origin and antibodies used in our kits (e.g., antibody targets conformational epitope rather than linear epitope), some native or recombinant proteins from other manufacturers may not be recognized by our products.

Principle of the Assay

The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human UBQLN2. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human UBQLN2. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human UBQLN2, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human UBQLN2 in the samples is then determined by comparing the OD of the samples to the standard curve.

For use with: Tissue homogenates, cell lysates, and other biological fluids.

For Research Use Only. Not for use in diagnostic procedures.

Target Information

Plays an important role in the regulation of different protein degradation mechanisms and pathways including ubiquitin-proteasome system (UPS), autophagy and the endoplasmic reticulum-associated protein degradation (ERAD) pathway. Mediates the proteasomal targeting of misfolded or accumulated proteins for degradation by binding (via UBA domain) to their polyubiquitin chains and by interacting (via ubiquitin-like domain) with the subunits of the proteasome (PubMed:10983987). Plays a role in the ERAD pathway via its interaction with ER-localized proteins FAF2/UBXD8 and HERPUD1 and may form a link between the polyubiquitinated ERAD substrates and the proteasome (PubMed:24215460, PubMed:18307982). Involved in the regulation of macroautophagy and autophagosome formation; required for maturation of autophagy-related protein LC3 from the cytosolic form LC3-I to the membrane-bound form LC3-II and may assist in the maturation of autophagosomes to autolysosomes by mediating autophagosome-lysosome fusion (PubMed:19148225, PubMed:20529957). Negatively regulates the endocytosis of GPCR receptors: AVPR2 and ADRB2, by specifically reducing the rate at which receptor-arrestin complexes concentrate in clathrin-coated pits (CCPs) (PubMed:18199683).

GENE ID 29978
SWISS PROT Q9UHD9
SYNONYMS CHAP1; CHAP1/DSK2; Dsk2; LIC-2; N4BP4; PLIC-2; PLIC2; NEDD4 Binding Protein 4; Protein linking IAP with cytoskeleton 2; Ubiquitin-like product Chap1/Dsk2

Materials Supplied

Kit Components 96 Wells Quantity/Size
Pre-Coated Microplate 48T: 6 strips x 8 wells; 96T: 12 strips x 8 wells
Standard (Lyophilized) 48T: 1 vial; 96T: 2 vials
Biotinylated Antibody (100×) 48T: 60 μL; 96T: 120 μL
Streptavidin-HRP (100×) 48T: 60 μL; 96T: 120 μL
Standard/Sample Diluent Buffer 48T: 10 mL; 96T: 20 mL
Biotinylated Antibody Diluent 48T: 6 mL; 96T: 12 mL
HRP Diluent 48T: 6 mL; 96T: 12 mL
Wash Buffer (25×) 48T: 10 mL; 96T: 20 mL
TMB Substrate Solution 48T: 6 mL; 96T: 10 mL
Stop Reagent 48T: 3 mL; 96T: 6 mL
Plate Covers 48T: 1 piece; 96T: 2 pieces

Storage

Storage *If the kit is opened, Store the whole kit at 4°C. If the kit is not used up in 1 week. Store the Pre-Coated Microplate, Standard ,Biotinylated Antibody and Streptavidin-HRP at -20°C, the rest reagents at 4°C, please used up within 6 months. *If the kit is not opened, store the whole kit: 4°C(short time storage, valid for 6 months); -20°C (long-term storage, valid for 1 year). Avoid repeated freeze-thaw cycles.

Performance Characteristics

REPEATABILITY Intra-assay Precision (Precision within an assay):CV% < 8% Three samples of known concentration were tested twenty times on 1 plate to assess intra-assay precision. Inter-assay Precision (precision between assays):CV% < 10% Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.
SENSITIVITY The minimum detectable dose was 0.63ng/mL.
ASSAY RANGE 1.57–100ng/mL
SPECIFICITY This assay has high sensitivity and excellent specificity for detection of Human UBQLN2. No significant cross-reactivity or interference between Human UBQLN2 and analogues was observed.

Frequently asked questions

What is Human Ubiquilin 2 (UBQLN2) ELISA Kit (BSKH73315) used for?

Human Ubiquilin 2 (UBQLN2) ELISA Kit is used for Sandwich Elisa.

Which species does Human Ubiquilin 2 (UBQLN2) ELISA Kit (BSKH73315) detect?

BSKH73315 is designed for Human samples.

Free sample offer

Try a recombinant sample

20 µL sample

Freewith your paid order

View product details (opens in a new tab)

View cart

US only. One sample per paid order, subject to review. Backorders may ship separately. Confirm Free at checkout. Check application and species suitability; same target does not guarantee equivalent performance. For research use only.

Primary antibody added to your cart

Need a secondary antibody?

Product validation image

Confirm application and cross-reactivity before use. Prices shown are before eligible cart discounts. Shipping and tax are calculated at checkout.

View cart