Help

EYA4 Polyclonal Antibody, AbBy Fluor-350 Conjugated

Applications

  • IF(IHC-P)
  • IF(IHC-F)
  • IF(ICC)

Predicted Reactivity

  • Human
  • Mouse
  • Rat
  • Dog
  • Cow
  • Sheep
  • Pig
  • Horse
Overview
Catalog # bs-13126R-BF350-100uL
Product Name EYA4 Polyclonal Antibody, AbBy Fluor-350 Conjugated
Applications
IF(IHC-P) IF(IHC-F) IF(ICC)
Predicted Reactivity Human, Mouse, Rat, Dog, Cow, Sheep, Pig, Horse
Specifications
Conjugation AbBy Fluor-350
Host Rabbit
Source KLH conjugated synthetic peptide derived from human EYA4
Clonality Polyclonal
Isotype IgG
Concentration 1ug/ul
Purification Purified by Protein A.
Storage Buffer Aqueous buffered solution containing 0.01M TBS (pH7.4) with 1% BSA, 0.02% Proclin300 and 50% Glycerol.
Storage Condition Store at -20C. Aliquot into multiple vials to avoid repeated freeze-thaw cycles.
Target
Gene ID 2070
Subcellular location Cytoplasm, Nucleus
Synonyms CMD1J; Deafness, autosomal dominant 10; DFNA 10; DFNA10; dJ78N10.1 eyes absent Drosophila homolog 4; dJ78N10.1 eyes absent; EYA 4; eya4; EYA4_HUMAN; Eyes absent 4; Eyes absent homolog 4 Drosophila; Eyes absent homolog 4; HGNC:3522; OTTHUMP00000040267.
Background A gene of chromosome 6q23 encodes the 640 amino acid protein, EYA4 (eyes absent) (1). EYA is one of four members of the eyes absent family (1). A 271 amino acid domain at the carboxyl terminal is highly conserved amongst the members of the eyes absent family (1). EYA4 is expressed in the craniofacial mesenchyme, the dermamyotome, and the limb (1). The conserved region in other EYA proteins interacts with SIX, DACH, and G-proteins, which regulate transcription in early embryonic development (1,2,3,4). SIX translocates EYA1-3 to the nucleus, and G-proteins can stop this interaction (3,4). Premature stop codon mutations in EYA4 cause postlingual, progressive autosomal dominant hearing loss in humans (2). This shows that EYA4 is also vital to the mature organ of Corti (2). EYA4 may cause oculo-dento-digital syndrome, based on its expression pattern and map postion (1).
Application Dilution
IF(IHC-P) 1:50-200
IF(IHC-F) 1:50-200
IF(ICC) 1:50-200

Frequently asked questions

Which applications is EYA4 Polyclonal Antibody, AbBy Fluor-350 Conjugated (bs-13126R-BF350) validated for, and at what dilution?

bs-13126R-BF350 is validated for IF(IHC-P) (1:50-200); IF(IHC-F) (1:50-200); IF(ICC) (1:50-200). These are recommended starting dilutions; optimal dilutions should be determined by the end user.

How should bs-13126R-BF350 be stored?

Store at -20C. Aliquot into multiple vials to avoid repeated freeze-thaw cycles. Storage buffer: Aqueous buffered solution containing 0.01M TBS (pH7.4) with 1% BSA, 0.02% Proclin300 and 50% Glycerol.

What immunogen was used to raise EYA4 Polyclonal Antibody, AbBy Fluor-350 Conjugated (bs-13126R-BF350)?

KLH conjugated synthetic peptide derived from human EYA4

What are the excitation and emission wavelengths of the AbBy Fluor-350 conjugate (bs-13126R-BF350)?

AbBy Fluor-350 on bs-13126R-BF350: excitation / emission 346nm/442nm.