FCHSD1 Polyclonal Antibody, Cy7 Conjugated
Applications
Reactivity
Predicted Reactivity
| Overview | |
| Catalog # | bs-8344R-Cy7 |
| Product Name | FCHSD1 Polyclonal Antibody, Cy7 Conjugated |
| Applications |
IF(IHC-P)
IF(IHC-F)
IF(ICC)
|
| Reactivity | Human, Mouse |
| Predicted Reactivity | Rat, Dog, Cow, Horse, Rabbit |
| Specifications | |
| Conjugation | Cy7 |
| Host | Rabbit |
| Source | KLH conjugated synthetic peptide derived from human FCHSD1 |
| Clonality | Polyclonal |
| Isotype | IgG |
| Concentration | 1ug/ul |
| Purification | Purified by Protein A. |
| Storage Buffer | Aqueous buffered solution containing 0.01M TBS (pH 7.4) with 1% BSA, 0.02% Proclin300 and 50% Glycerol. |
| Storage Condition | Store at -20C. Aliquot into multiple vials to avoid repeated freeze-thaw cycles. |
| Target | |
| Gene ID | 89848 |
| Subcellular location | Cytoplasm |
| Synonyms | FCH and double SH3 domains 1; FCH and double SH3 domains protein 1; FCHSD 1; FCHSD1; FCSD1_HUMAN; FLJ00007; Nervous wreck homolog 2; NWK 2; NWK2. |
| Background | FCHSD1 is a 690 amino acid protein that contains one FCH domain and two SH3 domains. FCHSD1 exists as three isoforms as a result of alternative splicing events. The gene encoding FCHSD1 maps to chromosome 5, which is associated with Cockayne syndrome through the ERCC8 gene and familial adenomatous polyposis through the adenomatous polyposis coli (APC) tumor suppressor gene. Treacher Collins syndrome is also chromosome 5 associated and is caused by insertions or deletions within the TCOF1 gene. Deletion of the p arm of chromosome 5 leads to Cri du chat syndrome. Deletion of 5q or chromosome 5 altogether is common in therapy-related acute myelogenous leukemias and myelodysplastic syndrome. |
| Application Dilution | |
| IF(IHC-P) | 1:50-200 |
| IF(IHC-F) | 1:50-200 |
| IF(ICC) | 1:50-200 |
Frequently asked questions
Which applications is FCHSD1 Polyclonal Antibody, Cy7 Conjugated (bs-8344R-Cy7) validated for, and at what dilution?
bs-8344R-Cy7 is validated for IF(IHC-P) (1:50-200); IF(IHC-F) (1:50-200); IF(ICC) (1:50-200). These are recommended starting dilutions; optimal dilutions should be determined by the end user.
Which species does FCHSD1 Polyclonal Antibody, Cy7 Conjugated (bs-8344R-Cy7) react with?
Tested reactivity: Human, Mouse. Predicted reactivity (expected from sequence homology but not yet tested): Rat, Dog, Cow, Horse, Rabbit.
How should bs-8344R-Cy7 be stored?
Store at -20C. Aliquot into multiple vials to avoid repeated freeze-thaw cycles. Storage buffer: Aqueous buffered solution containing 0.01M TBS (pH 7.4) with 1% BSA, 0.02% Proclin300 and 50% Glycerol.
What immunogen was used to raise FCHSD1 Polyclonal Antibody, Cy7 Conjugated (bs-8344R-Cy7)?
KLH conjugated synthetic peptide derived from human FCHSD1
What are the excitation and emission wavelengths of the Cy7 conjugate (bs-8344R-Cy7)?
Cy7 on bs-8344R-Cy7: excitation / emission 743nm/767nm.
