Help

Human Baculoviral IAP Repeat Containing Protein 7 (BIRC7) ELISA Kit

Due to the possibility of mismatching between antigens from other origin and antibodies used in our kits (e.g., antibody targets conformational epitope rather than linear epitope), some native or recombinant proteins from other manufacturers may not be recognized by our products.

Principle of the Assay

The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human BIRC7. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human BIRC7. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human BIRC7, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human BIRC7 in the samples is then determined by comparing the OD of the samples to the standard curve.

For use with: Serum, plasma, tissue homogenates, cell lysates, and other biological fluids.

For Research Use Only. Not for use in diagnostic procedures.

Target Information

Apoptotic regulator capable of exerting proapoptotic and anti-apoptotic activities and plays crucial roles in apoptosis, cell proliferation, and cell cycle control (PubMed:11162435, PubMed:11024045, PubMed:11084335, PubMed:16729033, PubMed:17294084). Its anti-apoptotic activity is mediated through the inhibition of CASP3, CASP7 and CASP9, as well as by its E3 ubiquitin-protein ligase activity (PubMed:11024045, PubMed:16729033). As it is a weak caspase inhibitor, its anti-apoptotic activity is thought to be due to its ability to ubiquitinate DIABLO/SMAC targeting it for degradation thereby promoting cell survival (PubMed:16729033). May contribute to caspase inhibition, by blocking the ability of DIABLO/SMAC to disrupt XIAP/BIRC4-caspase interactions (PubMed:16729033). Protects against apoptosis induced by TNF or by chemical agents such as adriamycin, etoposide or staurosporine (PubMed:11162435, PubMed:11084335, PubMed:11865055). Suppression of apoptosis is mediated by activation of MAPK8/JNK1, and possibly also of MAPK9/JNK2 (PubMed:11865055). This activation depends on TAB1 and MAP3K7/TAK1 (PubMed:11865055). In vitro, inhibits CASP3 and proteolytic activation of pro-CASP9 (PubMed:11024045).

GENE ID 79444
SWISS PROT Q96CA5
SYNONYMS KIAP; LIVIN; ML-IAP; MLIAP; RNF50; Melanoma Inhibitor Of Apoptosis Protein; Kidney Inhibitor Of Apoptosis Protein; Livin Inhibitor-Of-Apoptosis; RING finger protein 50

Materials Supplied

Kit Components 96 Wells Quantity/Size
Pre-Coated Microplate 48T: 6 strips x 8 wells; 96T: 12 strips x 8 wells
Standard (Lyophilized) 48T: 1 vial; 96T: 2 vials
Biotinylated Antibody (100×) 48T: 60 μL; 96T: 120 μL
Streptavidin-HRP (100×) 48T: 60 μL; 96T: 120 μL
Standard/Sample Diluent Buffer 48T: 10 mL; 96T: 20 mL
Biotinylated Antibody Diluent 48T: 6 mL; 96T: 12 mL
HRP Diluent 48T: 6 mL; 96T: 12 mL
Wash Buffer (25×) 48T: 10 mL; 96T: 20 mL
TMB Substrate Solution 48T: 6 mL; 96T: 10 mL
Stop Reagent 48T: 3 mL; 96T: 6 mL
Plate Covers 48T: 1 piece; 96T: 2 pieces

Storage

Storage *If the kit is opened, Store the whole kit at 4°C. If the kit is not used up in 1 week. Store the Pre-Coated Microplate, Standard ,Biotinylated Antibody and Streptavidin-HRP at -20°C, the rest reagents at 4°C, please used up within 6 months. *If the kit is not opened, store the whole kit: 4°C(short time storage, valid for 6 months); -20°C (long-term storage, valid for 1 year). Avoid repeated freeze-thaw cycles.

Performance Characteristics

REPEATABILITY Intra-assay Precision (Precision within an assay):CV% < 8% Three samples of known concentration were tested twenty times on 1 plate to assess intra-assay precision. Inter-assay Precision (precision between assays):CV% < 10% Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.
SENSITIVITY The minimum detectable dose was 0.057ng/mL.
ASSAY RANGE 0.16–10ng/mL
SPECIFICITY This assay has high sensitivity and excellent specificity for detection of Human BIRC7. No significant cross-reactivity or interference between Human BIRC7 and analogues was observed.

Frequently asked questions

What is Human Baculoviral IAP Repeat Containing Protein 7 (BIRC7) ELISA Kit (BSKH73537) used for?

Human Baculoviral IAP Repeat Containing Protein 7 (BIRC7) ELISA Kit is used for Sandwich Elisa.

Which species does Human Baculoviral IAP Repeat Containing Protein 7 (BIRC7) ELISA Kit (BSKH73537) detect?

BSKH73537 is designed for Human samples.

Free sample offer

Try a recombinant sample

20 µL sample

Freewith your paid order

View product details (opens in a new tab)

View cart

US only. One sample per paid order, subject to review. Backorders may ship separately. Confirm Free at checkout. Check application and species suitability; same target does not guarantee equivalent performance. For research use only.

Primary antibody added to your cart

Need a secondary antibody?

Product validation image

Confirm application and cross-reactivity before use. Prices shown are before eligible cart discounts. Shipping and tax are calculated at checkout.

View cart